产品介绍详情

 

Pressure Ratings will be governed by the tubing selected for a particular application. Working Pressures are calculated below for tubing using maximum allowable stress levels in accordance with ASME/ANSI B31.3, at ambient temperature.

承压等级由配套管材决定;下表工作压力依据常温、ASME/ANSI B31.3 工艺管道标准许用应力计算。


Tube O.D.
管材外径
Pressure Rating 额定压力Normal Wall Thickness
标准壁厚
Psigkgf/cm²
1/4in.51002581mm
3/8in.33002321mm
1/2in.35002461.24mm

Dimensions are for reference only and are subject to change.

尺寸仅供参考,如有变更恕不另行通知。

产品特点

 

FEATURES 产品特点

・采用 316L 不锈钢材质.316L Material

永久激光打码,材质可追溯至原厂材质质保书.Permanently Heat code marked; traceable to original mill certificate of test

电解抛光件在六角本体永久标识 EP 代号(P/PX)Electropolished components permanently marked with designator on cube (P or PX)

关键密封内壁 100% 灯光放大目视检测.Critical surfaces are 100% visually inspected using magnification and lighting


MATERIALS 材质标准

不锈钢材质符合以下标准:

Stainless Steel standards are in compliance with the below codes:

JIS G4303 /G3214/G5121 /G3459 /G3463

ASTM A479 /A276/A182 /A351/A312 /A269"

重熔不锈钢采用 VAR 真空电弧重熔工艺生产

Stainless Steel Remelted" is made of VAR (Vacuum Arc Remelting) material.



技术参数

 

使用说明

密封球面受损会影响管件密封性能。

所有金属面密封管件的密封球面均配有保护帽,防止磕碰、划伤。

仓储、搬运全程保留保护帽,仅装配前拆除。

带卡套定位组件装配步骤 

・步骤 1

使用垫片定位组件时,按图示轴向压入卡套;定位组件可将垫片固定在密封球面上。严禁划伤球面,否则会造成管件密封失效。

步骤 2

生成高清图片.jpg

无定位组件装配步骤

・步骤 1:将垫片放入母螺母内

生成高清图片 (2).jpg

步骤 2:组装所有零件,手拧至贴合

生成高清图片 (6).jpg

步骤 3:在公、母件六角平面做对齐标记

生成高清图片 (3).jpg

・步骤 4:固定背撑扳手不动,将母螺母在手紧基础上再拧紧 1/8 圈

生成高清图片 (4).jpg

警告:过度拧紧会损坏密封环面,存在泄漏风险。

拆卸说明

生成高清图片 (6).jpg

保护帽

已安装管路中拆卸金属面密封接头需预留极小操作间隙。拆卸时用背撑扳手固定公螺母 / 阀体六角,松开母螺母;零件拆下后,务必使用保护帽或垫片定位组件防护密封球面。